AERIAL QUICK CHANGE
Aerial Quick Change - on Spanish web
Aerial Rigging Specifications
-
Ceiling and floor rigging points must accommodate Working Load Limits of 1,000 lbs minimum (450 kilos)
-
Ceiling height 18' - 27' / 5.5 - 8.5 meters, (higher points can be accommodated with additional rigging on a case by case basis)
-
10' / 3 meters diameter clearance from all airspace around the rigging point
-
Rigging required for either a pulley pack or winch rated to human dynamic weight
-
Direct contact to the onsite rigger before the event scheduling and during the event’s duration
-
This act can be seen 360 degrees
Stage Specifications
-
Floor space 10' / 3 meters diameter clearance with no restraints up to rigging point
-
This act can be seen 360 degrees
Lighting Specifications
-
Minimum 3 light settings for the the aerial quick change act
-
Starting with blue, fuchsia, deep orange front, side and back lighting
-
Changing to blue tones for the moment before the quick change
-
Changing again immediately after the quick change to bright yellows and red
-
Amber follow spot at 50% throughout​
STAGE ILLUSION
Stage Illusion - Floating Table, Linking Rings & Magical Sands
Stage Specifications
-
Floor space 10' / 3 meters diameter clearance, preferably Marley dance flooring
-
The illusions can move in and out of frontal to 3/4 room view
Lighting Specifications
-
Purple, fuchsia & deep orange front, side and back lighting for FT & LR
-
Amber follow spot at 50% throughout
-
Yellows, red & deep orange cross side and back lighting lighting for Sands
-
Down spot over the front of the Sands bowl of water
GENERAL
On-site Needs and Specifications
Warm / temperate dressing room large enough for stretching and specialty prop storage
Healthy snacks and filtered waterPersonal Assistant for quick change dressing
Access to water to fill the Sands bowl
Transportation and Accommodations
PLEASE NOTE: Most of my acts require an assistant traveling with me
Equipment and costumes can be flown in 1 to 2 large checked luggage at 50lbs (22 kilos)
Direct flights when possible, longer flights should have a window or aisle option
(I do not fly with Spirit, Frontier Airlines OR other their respective international budget carriers)
Separate rooms for myself and my assistant

LEFT DIAGRAM
This system set up is for events that cannot accommodate a floor plate ancore.
RIGHT DIAGRAM
This system set up is for events that have floor plate installations
PHOTOS BELOW
These show a motor installation with adaptations for higher ceilings